Product Description
Biological Oxygen Demand (B.O.D.) Incubator P.I.D. Controller Based Models :
- Double walled in construction, gap between the two walls filled with high quality Polyurethane Foam (PUF)
- Incorporated with Microprocessor based Auto tuning type PID Temperature Indicating Controller cum Data Logger with Dual Display for Set & Process value indication. It has a storage of up to 500 readings and comes with a built-in RS-485 output. This enables the user to upgrade the system anytime down the line and download the data from the Controller onto the PC using a suitable hardware. In the event of power failure, Non-Volatile memory allows chamber to return to original set point when power is restored.
- Audio Visual Alarm in case of temperature deviation from set value.
- A highly accurate Pt-100 3 Wire RTD sensor is used for sensing of Temperature.
- Incorporated with additional temperature Hi/Lo cut-off safety system to cut-off compressor below +5c & to cut-off the heater above + 60c
- Anti-moisture entry at mouth of the cabinet using hot line method
- Full length inner acrylic door and outside metal door with S.S. lock & key provided.
- Food Grade Silicon gasket fitted on the Chamber and Magnetic Gasket fitted on outer metal door ensures zero leakage between the door & the Chamber.
- Provided with a motor-blower arrangement at the back for forced air circulation (2 Nos.for 800 Ltr. Cap & above) to ascertain temperature uniformity within the chamber
- Hermetically sealed CFC/HCFC Free Emerson Make Compressor unit utilizing R-134A an eco-friendly refrigerant with electronic time relay to safeguard the Compressor.
- Front lockable & back free heavy-duty castor wheels provided for easy moveability.
- Rod type Shelves provided are made of Stainless Steel
- Chambers of capacity 800 Ltr. and above are available with twin doors
- Provided with Validation Documents.
- Electrically operated on 230 V AC, 50 Hz. Single Phase supply.
Temperature Range : + 5C To + 60C
Temp. Accuracy : 0.5C
Temp. Uniformity : 2C
Standard Model :
Outer chamber made of Mild Steel (20 swg) duly powder coated and inner chamber made of Stainless Steel 304 grade (20 swg) Mirror finish.
GMP Model :
Outer chamber made of Stainless Steel 304 grade (20 swg) and inner chamber made of Stainless Steel 304 grade (20 swg) Mirror finish.
Specification
| CAT.NO. | CAPACITY | INTERNAL DIMENSION IN W x D x H (mm) | EXTERNAL DIMENSION IN W x D x H (mm) | SHELF |
| TBOD-100 / TBOD-100G | 100 L (3 Cu.Ft.) | 430 x 400 x 600 | 580 x 720 x 1290 | 02 |
| TBOD-120 / TBOD-120G | 120 L (4 Cu.Ft.) | 430 x 400 x 700 | 580 x 720 x 1390 | 03 |
| TBOD-165 / TBOD-165G | 165 L (6 Cu.Ft.) | 520 x 400 x 800 | 670 x 720 x 1490 | 03 |
| TBOD-200 / TBOD-200G | 200 L (8 Cu.Ft.) | 550 x 400 x 910 | 700 x 720 x 1600 | 03 |
| TBOD-300 / TBOD-300G | 300 L (10 Cu.Ft.) | 560 x 450 x 1200 | 710 x 770 x 1890 | 04 |
| TBOD-400 / TBOD-400G | 400 L (13 Cu.Ft.) | 630 x 530 x 1200 | 780 x 850 x 1890 | 04 |
| TBOD-600 / TBOD-600G | 600 L (20 Cu.Ft.) | 720 x 650 x 1300 | 870 x 970 x 1920 | 04 |
| TBOD-800 / TBOD-800G | 800 L (26 Cu.Ft.) | 1120 x 600 x 1300 | 1370 x 920 x 1920 | 06 |
| TBOD-1000/ TBOD-1000G | 1000 L (33 Cu.Ft.) | 1150 x 670 x 1300 | 1400 x 990 x 1920 | 08 |
| TBOD-1200/ TBOD-1200G | 1200 L (40 Cu.Ft.) | 1250 x 750 x 1300 | 1500 x 1070 x 1920 | 08 |
| TBOD-1500/ TBOD-1500G | 1500 L (50 Cu.Ft.) | 1300 x 890 x 1300 | 1550 x 1210 x 1920 | 08 |
| TBOD-2000/ TBOD-2000G | 2000 L (66 Cu.Ft.) | 1500 x 920 x 1460 | 1750 x 1350 x 1920 | 08 |
- In Cat. No. column G stands for GMP Models
- 800 Ltr. capacity & above models are available in two door system
OPTIONAL :
| CAT.NO. | OPTIONAL ACCESSSORIES |
| DS-4/8 | Four/Eight Channel programmable temperature Data Scanner for record, store & print data online and off line with variable print time intervals, suitable for 80 Col. dot matrix printers |
| DS-16 | Sixteen Channel programmable temperature Data Scanner for record, store and print the data online and off line with variable print time intervals, suitable for 80 col. dot matrix printers |
| TP_Suite 2.1 | TP_Suite 2.1 CFR 21 Part 11 compliance Windows based communication software for data management. Complete with RS-485 multi dropping to monitor multiple chambers (Tech Panacea Make) to one single software. |
| SRS | Ready to use stand by Refrigeration system in case if regular system fails. Complete with Compressor, Condenser and accessories (Only for 600 Ltrs & above Models) |
| SAS | Security Alarm System suitable for TECH PANACEA make 4 equipment alarm for deviations with LED indicators for identification with individual alarm acknowledgment button |
| GSM-5 | Mobile Alerts via GSM Technology in case of System failure (SIM Card in Customers scope) |
Precision Temperature ControlThe B.O.D. Incubator Std utilizes a digital PID microprocessor controller to achieve highly accurate temperature regulation, ensuring 0.5C accuracy and uniformity of 1C across the chamber. Its robust refrigeration and heating systems, with a temperature range from 5C to 60C, are ideal for sensitive biochemical and incubation processes.
Quality Construction & Energy EfficiencyCrafted with a double-walled structure, an inner SS 304 stainless steel chamber, and high-grade PUF insulation, this incubator provides enhanced thermal efficiency and corrosion resistance. The equipments energy-efficient design reduces power consumption while maintaining optimal performance, making it suitable for extensive laboratory use.
User-Friendly Operation and FlexibilityEquipped with adjustable and removable shelves, caster wheels, and a digital display, the B.O.D. Incubator Std offers adaptability and straightforward monitoring for various sample types. Standard accessories include a power cord and user manual, while optional humidity control and internal lighting add further operational versatility.
FAQs of B.O.D. Incubator Std:
Q: How does the B.O.D. Incubator Std maintain uniform temperature throughout the chamber?
A: The incubator employs a digital PID microprocessor-based controller combined with high-grade PUF insulation, ensuring minimal heat loss and consistent temperature distribution within 1C across every part of the 112-liter chamber.
Q: What are the primary applications of the B.O.D. Incubator Std?
A: This incubator is primarily used for Biochemical Oxygen Demand (BOD) testing and incubation of biological or chemical samples in laboratories, supporting reliable and controlled environments for critical processes.
Q: When is it necessary to use the optional humidity control feature?
A: Optional humidity control may be required for experiments or sample incubations that demand regulated moisture levels to prevent sample drying or to replicate specific environmental conditions. You can request this feature based on your application needs.
Q: Where can the B.O.D. Incubator Std be installed?
A: Due to its robust construction and mobility features, including caster wheels, the incubator is suitable for use in research laboratories, pharmaceutical facilities, and testing institutes, requiring only a 220V, 50Hz AC power supply and ambient temperatures between 10C and 45C.
Q: What process safeguards are installed for temperature variations?
A: An integrated audio/visual alarm system is built into the B.O.D. Incubator Std to promptly alert users to any temperature deviations, ensuring sample integrity and equipment safety during operation.
Q: How can I adjust or remove the shelves inside the incubator?
A: The shelves in the B.O.D. Incubator Std are designed to be both removable and adjustable, allowing users to customize the chamber layout for different sample sizes and experiment configurations.
Q: What are the benefits of the double-layered glass and chamber illumination?
A: Double-layered glass provides clear visibility of samples while minimizing temperature loss, and the internal lamp ensures proper illumination for easy monitoring without frequently opening the chamber door.